Table 2 JYME1S004-FM147 Series Electrical Parameters
|  | Name | Parameters | Remark | 
| Minimum | Typical | Maximum | Unit | 
| 1 | Main Power | +3.1 | +3.6 | +3.7 | V |  | 
| 2 | Battery undervoltage point | 3.1 |   | 3.4 | V
 |  | 
| 3 | Quiescent operating current
 | 3 |   | 6 | uA | No communication | 
| 4 | Dynamic operating current
 | 6 |   |  9 | uA |  | 
| 5 | Remote power supply voltage |  | 3.6 |   | V |  | 
| 6 | Remote power supply current |  | 1 |   | mA |  | 
| 7 | Operating current during communication |  | 500 |  | uA | Valve does not move | 
| 8 | Continuous communication interval | 180 |  | 480 | mS |  | 
| 9 | Continuous Working Time | 6 |  |  | year | 2.2Ah battery, remaining power is greater than 70% after six years | 
| 10 | Communication rate |  | 2400 |   | bd |  | 
| 11 | Communication distance |   | 1 | 2 | km | Depends on the number of loads | 
| 12 | M-BUS voltage | 24 | 30 | 36 | V |   | 
| RS-485 voltage
 | 7.5 | 15 | 24 | V |   | 
| 13 | Normal Operating Temperature | -10 |  | 50 | ℃ | No LCD screen | 
| 14 | Extreme operating temperature
 | -20 |  | 60 | ℃ |   | 
| 15 | Storage Temperature | -30 |  | 70 | ℃ |   | 
| 16 | Humidity
 |  | 85% |   |   |   | 
| 17 | Motor drive timeout waiting time
 |  | 25 |   | S |   | 
| 18 | Motor stall current
 |  | 30 | 180 | mA |   | 
 
Mechanical Dimensions
 

 
Figure 2 JYME1S004-FM147 Series Dimension Drawing
 
| Caliber(mm) | L(mm) | H(mm) | M(mm) | Weight(kg) | 
| 50 | 139 | 165 | 94 | 2.66 | 
| 40 | 139 | 165 | 74 | 2 | 
| 32 | 139 | 165 | 52 | 1.55 | 
 