MBUS-RS485 Water Meter Wired With Valve

JYME1S004-LXLCY-V Series Wired Direct Water Meter is a smart water meter based on MBUS / RS485 standard communication protocol.

Product Description

JYME1S004-LXLCY-V Series Wired Direct Water Meter is a smart water meter based on MBUS/RS485 standard communication protocol. The distance is far from the network. Easy to write reading and controlling water meters, realizing remote direct reading of water meters, effectively avoiding the management department on top table reading, and improving meter reading efficiency.

 

The water meter is designed with an electromechanical separation structure, and the measurement is accurate. The base table and the wired acquisition electronic unit can be completely separated, and each independently operate, it is convenient to install, which is convenient for later maintenance. The base table and the wireless acquisition module can be completely separated, and the collecting portion can be connected to Tianshi, Kent, Siemens, Sheshus, Wei Min and miniature sensors, to achieve collection signals, convenient measurement. Each independent operation is convenient to install, which is convenient for later maintenance.

 

Model:

JYME1S004-LXLCY-V MA611T

 

Brand:

JinYuMing

 

Table 2 JYME1S004-LXLCY-V Series Electrical Parameters

 

Name

Parameters

Remark

Minimum

Typical

Maximum

Unit

1

Main Power

+2.7

+3.6

+3.7

V

 

2

Battery undervoltage point

3.1

 

3.4

V

 

3

Quiescent operating current

3

 

6

uA

Not connected to the reed switchmagnetoresistive sensor, no communication

4

Dynamic operating current

6

 

 9

uA

 

5

M-BUS remote power supply voltage

 

3.6

 

V

 

6

M-BUS remote power supply current

 

1

 

mA  

7

Operating current during communication

 

500

 

uA

Reed switch/magnetoresistive sensor not working

8

Continuous communication interval

180

 

480

mS

 

9

Continuous Working Time

6

    year 4.0Ah battery, remaining power is greater than 70% after six years

10

Communication rate

  2400

 

bd  

11

Communication distance

 

1

2

km

Depends on the number of loads

12

MBUS voltage

24

30

36

V

 

RS485 voltage

7.5

15

24

V

 

13

Normal Operating Temperature

-10  

50

 

14

Extreme operating temperature

-20  

60

 

15

Storage Temperature

-30  

70

 

16

Humidity

  85%

 

 

 

17

Motor drive timeout waiting time

 

25

 

S  

18

Motor stall current

 

30

70

mA  

 

Table 3 JYME1S004-LXLCY-V Series Power Consumption

 

 

Current consumption details

Current parameters

Each Duration

Each Time Interval

Annual power consumption (AH)

Size

Unit

1

Motherboard quiescent operating current

6

uA

     

0.06

2

MCU wake-up power consumption

300

uA

1 mS/time 172,800 times per day

0.0053

3

Battery self-depletion

 

       

0.1

4

Valve power consumption

170

mA

25

S/time

1 time per month

0.014

5

Total

         

0.17~0.22

 

Mechanical Dimensions

 

 

Figure 2 JYME1S004-LXLCY-V Series Dimension Drawing

 

Caliber(mm)

Length L1(mm)

Length L(mm)

Width B(mm)

Height H(mm)

Threaded connection

D

R

15

165

259

98

116

G3/4

R1/2

20

195

299

98

117

G1

R3/4

25

225

345

104

124

G11/4

R1

32

458

336

104

124

G11/2

R11/4

40

444

316

117

172

G2

R11/2

50

300

520

125

172

G21/2

R2

280

165(flange outer diameter)

188

Flange connection 8-M16

 

Caliber(mm)

Length L(mm)

Height H(mm)

Flange outer diameter ΦD1 (mm)

Bolt hole center circle diameter ΦD2 (mm)

Threaded connection

50

416

279

165

125

4-M16

65

416

286

185

145

4-M16

80

481

316

200

160

8-M16

100

534

331

220

180

8-M16

125

560

388

250

210

8-M16

150

610

413

285

240

8-M120

200

725

475

340

295

8-M20(1.0MPa)
12-M20(1.6MPa)

 

CE1.pdf

CE2.pdf

Environmental Management Certificate.pdf

Quality System-Iso 9001.pdf

Enterprise Credit Rating Certificate.tif

Five-Star After-Sales Service Certificate.pdf

 

SEND INQUIRY