MBUS-IC Card Water Meter Wired

JYME1S004-LXS-E Series Wired Valve RF Card Water Wiume is a read smart water meter based on MBUS standard communication protocol. Wired MBUS technology communication, communication distance is far, convenient for networking.

Product Description

JYME1S004-LXS-E Series Wired Valve RF Card Water Wiume is a read smart water meter based on MBUS standard communication protocol. Wired MBUS technology communication, communication distance is far, convenient for networking. Easy to write reading and controlling water meters, realizing remote direct reading of water meters, effectively avoiding management departments on table meter reading, improving meter reading efficiency, with amplifier recharge function.

 

The water meter is designed with an electromechanical separation structure, and the measurement is accurate. The base table and the wired acquisition electronic unit can be completely separated, and each independently operate, it is convenient to install, which is convenient for later maintenance.

 

Model:

JYME1S004-LXSZ-E MA611T

 

Brand:

JinYuming

 

Table 2 JYME1S004-LXS-E Series Electrical Parameters

 

Name

Parameters

Remark

Minimum

Typical

Maximum

Unit

1

Main Power

+2.7

+3.6

+3.7

V

 

2

Battery undervoltage point

3.1

 

3.4

V

 

3

Quiescent operating current

3

 

6

uA

Not connected to the reed switchmagnetoresistive sensor, no communication

4

Dynamic operating current

6

 

 9

uA

 

5

Remote power supply voltage

 

3.6

 

V

 

6

Remote power supply current

 

1

 

mA  

7

Operating current during communication

 

500

 

uA

Reed switch/magnetoresistive sensor not working

8

Continuous communication interval

180

 

480

mS

 

9

Continuous Working Time

6

    year 4.0Ah battery, remaining power is greater than 70% after six years

10

Communication rate

  2400

 

bd  

11

Communication distance

 

1

2

km

Depends on the number of loads

12

M-BUS voltage

24

30

36

V

 

13

Normal Operating Temperature

-10  

50

 

14

Extreme operating temperature

-20  

60

 

15

Storage Temperature

-30  

70

 

16

Humidity

  85%

 

 

 

17

Motor drive timeout waiting time

 

25

 

S  

18

Motor stall current

 

30

180

mA  

 

Table 3 JYME1S004-LXS-E Series Power Consumption

 

 

Current consumption details

Current parameters

Each Duration

Each Time Interval

Annual power consumption (AH)

Size

Unit

1

Motherboard quiescent operating current

20

uA

     

0.2

2

MCU wake-up power consumption

300

uA

1 mS/time 172,800 times per day

0.0053

3

Battery self-depletion

 

       

0.1

4

Valve power consumption

1700

mA

25

S/time

1 time per month

0.0014

5

Total

         

0.32~0.372

 

Mechanical Dimensions

 

   

 

Figure 2 JYME1S004-LXS-E Series Dimension Drawing

 

Caliber

L1

L2

L3

H

M

D

Weight
 

Unit/mm

Unit/kg

15

259

165

13

104

115

G1/2B

1.34

20

299

195

13

104

115

G3/4B

1.55

25

345

225

13

104

115

G1B

1.75

 

CE1.pdf

CE2.pdf

Environmental Management Certificate.pdf

Quality System-Iso 9001.pdf

Enterprise Credit Rating Certificate.tif

Five-Star After-Sales Service Certificate.pdf

 

Related Products

SEND INQUIRY

Verify Code