JYME1S004-LXS-E Series Wired Valve RF Card Water Wiume is a read smart water meter based on MBUS standard communication protocol. Wired MBUS technology communication, communication distance is far, convenient for networking. Easy to write reading and controlling water meters, realizing remote direct reading of water meters, effectively avoiding management departments on table meter reading, improving meter reading efficiency, with amplifier recharge function.
The water meter is designed with an electromechanical separation structure, and the measurement is accurate. The base table and the wired acquisition electronic unit can be completely separated, and each independently operate, it is convenient to install, which is convenient for later maintenance.
Model:
JYME1S004-LXSZ-E MA611T
Brand:
JinYuming
Table 2 JYME1S004-LXS-E Series Electrical Parameters
|
Name
|
Parameters
|
Remark
|
Minimum
|
Typical
|
Maximum
|
Unit
|
1
|
Main Power
|
+2.7 |
+3.6
|
+3.7
|
V
|
|
2
|
Battery undervoltage point
|
3.1 |
|
3.4
|
V
|
|
3
|
Quiescent operating current
|
3 |
|
6
|
uA
|
Not connected to the reed switchmagnetoresistive sensor, no communication |
4
|
Dynamic operating current
|
6 |
|
9
|
uA
|
|
5
|
Remote power supply voltage
|
|
3.6
|
|
V
|
|
6
|
Remote power supply current
|
|
1
|
|
mA |
|
7
|
Operating current during communication
|
|
500
|
|
uA
|
Reed switch/magnetoresistive sensor not working |
8
|
Continuous communication interval
|
180
|
|
480
|
mS
|
|
9
|
Continuous Working Time
|
6
|
|
|
year |
4.0Ah battery, remaining power is greater than 70% after six years |
10
|
Communication rate
|
|
2400 |
|
bd |
|
11
|
Communication distance
|
|
1 |
2
|
km
|
Depends on the number of loads
|
12
|
M-BUS voltage
|
24 |
30
|
36
|
V
|
|
13
|
Normal Operating Temperature
|
-10 |
|
50
|
℃ |
|
14
|
Extreme operating temperature
|
-20 |
|
60
|
℃
|
|
15
|
Storage Temperature
|
-30 |
|
70
|
℃
|
|
16
|
Humidity
|
|
85% |
|
|
|
17
|
Motor drive timeout waiting time
|
|
25 |
|
S |
|
18
|
Motor stall current
|
|
30 |
180
|
mA |
|
Table 3 JYME1S004-LXS-E Series Power Consumption
|
Current consumption details
|
Current parameters
|
Each Duration
|
Each Time Interval
|
Annual power consumption (AH)
|
Size
|
Unit
|
1
|
Motherboard quiescent operating current
|
20
|
uA
|
|
|
|
0.2
|
2
|
MCU wake-up power consumption
|
300
|
uA
|
1 |
mS/time |
172,800 times per day |
0.0053
|
3
|
Battery self-depletion
|
|
|
|
|
|
0.1
|
4
|
Valve power consumption
|
1700
|
mA
|
25
|
S/time
|
1 time per month
|
0.0014
|
5
|
Total
|
|
|
|
|
|
0.32~0.372
|
Mechanical Dimensions

Figure 2 JYME1S004-LXS-E Series Dimension Drawing
Caliber
|
L1
|
L2
|
L3
|
H
|
M
|
D
|
Weight |
|
Unit/mm
|
Unit/kg
|
15
|
259
|
165
|
13
|
104
|
115
|
G1/2B
|
1.34
|
20
|
299
|
195
|
13
|
104
|
115
|
G3/4B
|
1.55
|
25
|
345
|
225
|
13
|
104
|
115
|
G1B
|
1.75
|
CE1.pdf
CE2.pdf
Environmental Management Certificate.pdf
Quality System-Iso 9001.pdf
Enterprise Credit Rating Certificate.tif
Five-Star After-Sales Service Certificate.pdf