Send Inquiry

DN50-D200 Fully Automatic Water Meter Test Bench (Volumetric Method + Master Meter Method)

Test Meter Types: Ordinary mechanical water meter, ultrasonic water meter, smart water meter, electromagnetic flow meter

Product Description

Product Introduction

1. High production efficiency;

2. Fast input method: Wireless barcode scanner input for form numbers, fast, accurate, and convenient;

3. Energy saving, water saving, electricity saving, and labor saving;

4. Compact size: Saves space, fully automated, shared network, and saves auxiliary materials;

5. Novel structure: 304 stainless steel piping, novel and elegant appearance.

Detailed product information: Please ask sales personnel.

 

Product Models: JYM-50-200-5-AW-HZS4.0, JYM-50-200-2-AWS-HZS4.0

 

Device Uncertainty Urel≤0.2%k=2
Flow Stability 1.0% for startstop method; 0.2% for other methods
Test Medium Purified tap water
Operating Humidity ≤ 93% RH
Operating Water Temperature 20  ± 10 
Water Temperature Fluctuation in Single Measurement Water temperature fluctuation in a single measurement
Water Fluctuation Coefficient per Cycle ≤ ± 0.1%
Water Source Working Pressure 0.0–0.5 MPa, adjustable
Air Source Working Pressure 0.4–0.7 MPa
Device Operating Temperature 4–50 
Number of Meters Under Test DN50: 3 pcs | DN65, DN80: 2 pcs | DN100, DN150, DN200: 1 pc
Water Pump 1 pc: H=30 m, Q=1 m³/h, P=0.5 kW
1 pc: H=30 m, Q=40 m³/h, P=7.5 kW
1 pc: H=35 m, Q=200 m³/h, P=30 kW
1 pc: H=30 m, Q=600 m³/h, P=75 kW
Water Tank 45 m³
Commutator DN25, DN50, DN100, DN200 crossfork pneumatic open commutator; low noise, high sensitivity; travel difference < 10 ms; uncertainty within 0.002%
Meter Clamping Mechanism Dualcylinder outwardpush series pneumatic clamping mechanism; single pneumatic clamps for front 10 and rear 5 positions
Water Meter Seal Test Pressure range: (0–2.0) MPa
Bore Diameter Φ50 mm, telescopic stroke ≥ 80 mm
Timer (10–100) kHz (adjustable); better than 10⁻⁶
Calibration Signal Pulse signal, f = (0–10) kHz
Vacuum System Differential pressure vacuum generator; vacuum water filling to keep water meters fully filled
Supported Operation Modes Fully automatic, semiautomatic, touchscreen manual operation
Acquisition Equipment 3 sets of mobile phones with 40 MP resolution, 8G/128G storage
Standard Device Volumetric Method + Master Meter Method
Flow Range 0.010-630m³/h
Calibration Method Startstop method Diversion method Flow–Time Method QTY
Electromagnetic Flow Meter
Instantaneous Flow Display
Advanced (Class 0.5)
DN10:20-500L/H 1
DN40:2260-22600L/H 1
DN100 10-200m³/H 1
DN200 56.55-630m³/H 1
Electromagnetic Flow Meter
Standard Meter Standard
(Class 0.2–0.3)
DN10:20-500L/H 1
DN40:2260-22600L/H 1
DN100 10-200m³/H 1
DN200 56.55-630m³/H 1
Volumetric Vessel
Volumetric Method Standard
50L-100L 1
1000L-2000L 1
5000L-10000L 1

SEND INQUIRY