Send Inquiry

DN15-D25 Fully Automatic Liquid Flow Test Bench(Piston + Mass + Master Meter Method)

Product Description

Product Introduction

1. High Production Efficiency: 200 water meters can be tested in eight hours.

2. Fast Input Method: Wireless barcode scanner input of meter numbers—fast, accurate, and convenient.

3. Energy Saving and Consumption Reduction: Saves water, electricity, and labor.

4. Compact Size: Saves space, fully automated, shares a network, and reduces auxiliary materials.

5. Novel Structure: European standard aluminum profile frame, 304 stainless steel piping, novel and stylish appearance.

Detailed product information: Please request from sales personnel.

 

Product Model: JYM-15-25-10-AZ-HS4.0

 

Device Uncertainty Urel≤0.05%(k=2)
Urel≤0.05%(k=2)
Flow Stability 1.0% for startstop method; 0.2% for other methods
Test Medium Purified tap water
Operating Humidity ≤ 93% RH
Operating Water Temperature 20  ± 10 
Water Temperature Fluctuation in Single Measurement Water temperature fluctuation in single measurement
Water Fluctuation Coefficient per Cycle ≤ ± 0.1%
Water Source Working Pressure 0.0–0.5 MPa (adjustable)
Air Source Working Pressure 0.4–0.7 MPa
Device Operating Temperature 4–50 
Number of Meters Under Test DN15: 10 pcs | DN20: 8 pcs | DN25: 6 pcs | Vertical water meters DN15DN20DN25: 6 pcs
Water Pump Nanfang CHM1050; flow rate 8 m³/h, head 48 m,1pc
Water Tank 800 L
Commutator DN25 crossfork pneumatic open commutator; low noise, high sensitivity; travel difference < 10 ms; uncertainty within 0.002%
Meter Clamping Mechanism Dualcylinder outwardpush seriesconnected pneumatic clamps; 10 front & 5 rear with single pneumatic clamps
Water Meter Seal Test Pressure range (0–2.0) MPa
Bore Diameter Φ50 mm, telescopic stroke ≥ 80 mm
Timer (10–100) kHz (adjustable); better than 10⁻⁶
Calibration Signal Pulse, f = (0–10) kHz
Vacuum System Differential pressure vacuum generator; vacuum water filling to keep meters fully filled
Supported Operation Modes Fully automatic, semiautomatic, touchscreen pure manual
Acquisition Equipment 16 sets of mobile phones with ≥ 40megapixel resolution
Standard Device Piston + Mass + Master Meter Method
Flow Range 0.003-8m³/h
Calibration Method Startstop method Diversion method Flow–Time Method QTY
Electromagnetic Flow Meter
Instantaneous Flow Display
Advanced (Class 0.5)
DN23-90L/H 1
DN1020-500L/H 1
DN25500-800L/H 1
Electromagnetic Flow Meter
Standard Meter Standard
(Class 0.2–0.3)
DN23-90L/H 1
DN1020-500L/H 1
DN25500-800L/H 1
Electronic Scale
Mass Method Standard
Max=30kg6000e 1
Max=150kg15000d 1

SEND INQUIRY